OmniBox

Top bar: windows and menus

The top bar of the web interface opens the unit's settings windows (network, system, SD card, DMX editor, backup, clock) and groups together the project, block and edit menus, the language selector and the connection indicators.

How the bar is laid out

  • On the left, seven buttons each open a window: Network, System, HID Debug, SD card, DMX Editor, Backup, Clock. The button stays highlighted while its window is open; a second click closes it.
  • On the right: the ⚑ Presets and 💾 SD projects lists, the 📁 File, ▦ Blocks and ✎ Edit menus, the language selector, then the connection indicators.

Windows are moved by their title bar and resized by their bottom-right corner. The □ button switches them to full screen (Full screen / Restore), ✕ closes them. On a narrow screen, the bar wraps onto two lines.

Tutorial 2 — The menus

Network

Network Settings window
The Network Settings window.
SettingValuesEffect
Current IPread-onlyAddress actually in use right now (fixed or assigned by DHCP).
ModeStatic IP / DHCPFixed address, or assigned by the network.
Static IPa.b.c.dFixed address, used in Static IP mode.
Subnet Maska.b.c.dSubnet mask for the fixed address.

Apply asks for confirmation (“The unit will restart; reconnect to the new IP”), stores the settings and then restarts the unit: the network stack only reads its configuration at start-up.

A badly formed address or mask is ignored without any message, but the restart still happens: the unit comes back with the old value. Check what you typed before applying.

Same settings on the unit itself: Reseau page on the screen.

System

Identity

SettingValuesEffect
Long name63 characters max.Name of the unit on the network: reply to Art-Net consoles, sACN source name, name seen by the USB tool.
Short name17 characters max.Short name announced over Art-Net.
Firmwareread-onlyFirmware version, in the form of a build date.
Serialread-onlyUnique identifier of the unit's processor.

To find out whether a newer version exists, compare the date shown in Firmware with that of the latest published update. See the available updates (page in French) →

Security

SettingValuesEffect
Login pageDisabled / EnabledWhen enabled, network access is supposed to ask for a username and password (“Protected access — Omnibox” window) every time the page loads. USB access is not supposed to ask for them.
Username15 characters max.Username requested.
Password15 characters max.Password requested.
In the current firmware, setting Login page to Enabled locks you out of the interface, over the network and over USB alike: the connection is refused even with the right credentials. Only a reset through a firmware update unlocks the unit, at the cost of its entire configuration. Leave this setting on Disabled. A restore from the Backup window also applies this setting: check the file first.

Apply stores the identity and security settings, without restarting.

Factory reset and DFU

  • Reset (factory reset, after confirmation) deletes all modules, restores the factory configuration (network in DHCP, name, credentials, login page disabled) and then restarts.
  • DFU (after confirmation) restarts the unit in firmware update mode; it disconnects from the interface.
Export your project (File menu) or a full backup (Backup) before either of these actions: the factory reset erases the patch, and a firmware update also erases the configuration stored in the unit.

HID Debug

Diagnostic console, mainly useful for support. Despite its name, it works just as well over USB as over the network.

  • The top field sends a request to the unit (for example params/network): Send or Enter. The command and the reply are shown in the log.
  • Firmware log scrolls the unit's internal log. The Filter field only keeps lines containing a given text (e.g. AUDIO_); the aud, dmx, net, mod, fls, gen, sd boxes select the categories. A red overflow counter flags lost lines.
  • The log keeps the last 300 lines. The interface's communication errors are also written to it. Copy puts it on the clipboard, Clear empties it.

SD card

File manager for the card. The top bar shows the current folder and the free space out of the total capacity (or “No SD card”). Folders first, then files, in alphabetical order; the bottom shows the number of folders and files.

CommandEffect
ClickSelects the item.
Double-clickOpens a folder, or downloads a file.
↩Goes up one folder.
⟳ RefreshRe-reads the card.
UploadSends a file from the computer to the current folder, with a progress display.
FolderCreates a folder in the current folder.
RenameRenames the selected item.
DeleteDeletes the selected item, after confirmation.
DownloadCopies the selected file to the computer.

The characters \ / : * ? " < > | are not allowed in names.

An uploaded file replaces a file with the same name without confirmation. A file opened by a module (player, recorder, audio player) cannot be replaced, renamed or deleted: stop the module first. A folder that is not empty cannot be deleted.

Tests and speed

  • SD test writes and then reads back 10 MB and gives the transfer rates, the slowest block and the number of blocks taking more than 10 ms, with a rating from “Very slow — not recommended” to “Excellent”.
  • File test measures reading of the selected file.
  • SD card speed: Normal (24 MHz) or Fast (48 MHz). The card is re-initialised immediately; if it does not respond at the new speed, the unit goes back to the previous one. The choice is saved.
The tests block the unit for anything from a few seconds to a minute depending on the card. Do not run them during a show.

DMX Editor

DMX Editor with a sequence open
A sequence open: the timeline at the top, the universes at the Start and End markers at the bottom.

The editor touches up the .dmx sequences on the SD card, the ones produced by the DMX recorder and played by the DMX player.

  • Open chooses a .dmx file on the card. Save rewrites the open file, Save As asks for a new name. Compression Yes only writes the channels that change, No writes every frame in full.
  • The timeline shows one row per channel (U0 A1 = universe 0, address 1) with time running from left to right: the height and colour of the bars show the value. The mouse wheel scrolls through the channels; two scroll bars handle scrolling.
  • Clicking a cell selects it; DMX value then changes its value (0 – 255). The bottom of the window sums up the sequence (number of frames, universes, duration) and the cell under the mouse.
  • The Start (green) and End (blue) markers are placed with a right-click (Mark start (in), Mark end (out)), or by holding the click for a quarter of a second and then dragging. The two grids at the bottom show the universe at each of the two markers.
ButtonEffect
↺ / ↻Undo / Redo (12 steps).
✂ Cut the selectionDeletes the section between Start and End; everything after it is moved earlier by the same amount.
🔁 Trim outside in/outKeeps only the section between Start and End.
🔀 Fade between 2 pointsAfter a drag selection: replaces the intermediate values of each selected channel with a steady rise or fall between the first and last frame.

Hovering over the ✂ and 🔁 buttons highlights the part of the timeline that will be deleted.

To cut the silences at the start and end of a take: place Start and End on the useful part, then Trim outside in/out.
Closing the editor with unsaved changes asks for confirmation, then loses them: the editor starts empty the next time it is opened.

Backup

Backup / Restore window
The Backup / Restore window.

The Backup / Restore window saves the unit's complete state to a .json file: the patch (modules, settings, links, blocks, exposed ports), the network (mode, address, mask) and the system (names, login page, credentials). The firmware version and serial number are never restored.

  • Export → Download JSON: file <name>_backup.json, based on the unit's long name.
  • Import → Browse…: the file is checked, then a preview shows the unit's name, its address (or DHCP) and the number of modules. Apply config restores everything, after confirmation if the file contains a patch: the current patch is replaced.
Restored network settings only take effect at the next restart. The file contains the username and password in plain text: store it accordingly.

Older backups (node1_backup format) are accepted for their network and system settings.

The File menu only exports the patch, to carry from one unit to another. Backup also saves the identity and network settings of this particular unit.

Clock

Real-time clock window
The Real-time clock window.
  • Current reading: date and time read from the clock when the window was opened; ↻ reads it again. The fields are pre-filled with this value.
  • Date, Time (including seconds): values to write. Day is calculated from the date.
  • PC time copies the computer's time into the fields; Apply writes it to the clock, then reads it back.

Possible messages: “RTC missing / I2C silent” if the clock is not responding, and “OK — ⚠ RTC weekday inconsistent, apply again to fix it” if the stored day of the week does not match the date. An Apply recalculates it.

The clock is used by the Time window and Calendar modules. It can also be set from the unit's screen.

Presets and SD projects

  • ⚑ Presets: projects supplied with the firmware, read-only.
  • 💾 SD projects: .omni files on the SD card, stored in the projects/ folder or left in the root. When the same name exists in both places, the folder is shown.

The lists are re-read every time they are opened. Hovering over an entry shows its path and the project comment. Choosing an entry loads the project; if the workspace is not empty, a confirmation warns you that it will be cleared.

File menu

The File menu saves and reloads the whole workspace as a .omni project: modules, settings, links, blocks, exposed ports and execution order.

EntryEffect
Save to PCDownloads the project. Suggested name: that of the last project loaded, otherwise projet.omni.
Save to SDAsks for a name and writes the project to projects/ on the card; it then appears in SD projects.
Load from PCOpens a .omni file from the computer.
Load from SDChooses a .omni file on the card.
Comment…Project description, 128 characters max., stored in the file and shown on hover in the project lists.
Clear allDeletes all modules and all blocks, after confirmation (“This cannot be undone”).

Loading a project replaces the workspace, after confirmation if it is not empty. The physical ports and network universes of the old project are released. A project exported by an older firmware is brought into line with the current port layout on import.

The comment is not kept by the unit: it goes with the next save of the project. Save the project after typing it.

Blocks menu

This menu saves and reloads a single block (.bloc file), so you can reuse it in another project.

EntryEffect
Save block to PCDownloads the selected block.
Save block to SDAsks for a name and writes the block to the root of the card.
Load block from PCInserts a block from a file on the computer.
Load block from SDInserts a block chosen from the card.
  • The two “Save” entries stay greyed out until a block is selected: click the block's title bar.
  • The file keeps the block's modules, their settings, their internal links and the exposed ports. Links to outside the block are not saved.
  • A loaded block arrives collapsed, in the centre of the view.
  • Blocks saved to the root of the card also appear in the Blocks / SD category of the catalogue: a click inserts the block in the centre of the view, a drag and drop places it where you want.

Tutorial 6 — Blocks

Edit menu

EntryShortcutEffect
CopyCtrl+CCopies the selected block or modules.
CutCtrl+XCopies then deletes, without confirmation.
PasteCtrl+VPastes the copy.
DeleteDel or BackspaceDeletes the selection, after confirmation. A block is deleted together with all its modules.
Select all (right-click only)Ctrl+ASelects all modules.
  • The entries are greyed out while nothing is selected, or there is nothing to paste.
  • Right-clicking the workspace opens the same commands; right-clicking a module or block that is not selected selects it first.
  • Where the paste lands: in the centre of the view from the menu, under the mouse with Ctrl+V, where you clicked with the right-click menu.
  • The copy carries the settings, internal links and exposed ports; the links to modules that were not copied are dropped. It does not take over the physical port or network universe reserved by the original.
  • The shortcuts have no effect while you are typing in a field.

Language

The FR / EN / DE / ES / IT selector changes the interface language immediately. The browser remembers your choice. Default module and port names are translated; a name you have typed yourself is shown as is.

Connection indicators

IndicatorMeaning
Dot before the addressGreen: Ethernet cable connected, link up. Grey: no link.
IP addressAddress the unit is currently using.
USB, flashing greenInterface opened over USB, unit reachable.
Disconnected, redInterface opened over USB, the unit is no longer responding.
USB, greyInterface opened over the network: the USB indicator does not apply.

If the unit stops responding, a Connection lost window covers the interface and the controls are disabled until the link is back: “Attempting to reconnect…”. It also appears with network access, even though its text mentions USB.